Septic Pump Not Working

If your septic tank will not begin there are three primary areas to examine for any issues The electronic system of the pump along with the pump's controls.

Septic Pump Not Working

If your septic tank will not begin there are three primary areas to examine for any issues The electronic system of the pump along with the pump's controls.

Electricity is extremely risky Be aware while working in the field of electricity. Also, switch off power supply breakers for testing the components of an electrical circuit. If you're not certain that you are able to perform any of these tests in a safe manner contact an expert.

Also Read: How to Find Septic Tank Cleanout

Electrical issues

If the pump doesn't appear to be operating in any way, doesn't respond to any tests , and isn't pumping effluent it could be due to an issue with the wiring. Check the circuit breaker and then use an instrument like a multimeter to inspect the wiring in the system to find out what needs to be replaced.

A fuse has been blown or a the circuit breaker has been activated. Examine fuses and circuit breakers. Replace fuses as necessary. Take note of the recommended size by the pump's manufacturer and the nameplate of the pump. Contact an electrician to fix the circuit in case it is needed.

The power cord of the pump is not wired properly and is not making good contact. If the system has an auxiliary plug-in, examine the prongs of the cap for the pump for corrosion and tightness. Install the new plug and scrub the prongs of the connector with abrasive papers, or replace the electrical receptacle.

The branch circuit is too small to support this pump's load. Make sure the line voltage is checked and compare it to manufacturer's specifications. The pump must be connected into its circuit breaker (or fuse). In the event that the circuit breaker is feeding electricity to other appliances or outlets then, install an outlet to allow the pump to have its own circuit breaker. Contact an electrician to fix the circuit.

The motor overload of the pump tripped. Let the pump cool for five to ten minutes, then reconnect it. If the overload occurs again then take the corrective action. Check the voltage of the line and then compare it with specifications of the manufacturer. A professional electrician or the power company examine the voltage of the branch circuit. The pump should be connected to an independent branch circuit.

Also Read: Rim Joist Size

The voltage is low. Voltage should be less or more than 10% of the motor's ratings. Verify that enough power is flowing through the system by measuring how much voltage is present at the control box, pressure switch and any other parts that power is passing through. If you discover that the power is high or too low from the control panel then you may require contacting with the company that supplies power. A low voltage at the pump could also result in thermal overload and shut down. Repair the electrical circuit, and then get in touch with the energy company.

Connections to the control panel and watertightness. Take the control panel for an inspection to identify indications of wear and tear. Examine for loose connections, as well as burned or melted parts. Checking the voltage of the control panel could have led to believe that it might be the cause of your issue.

Connections that are not working or a damaged conduit. Verify all electrical splices for signs of corrosion as well as other indicators that power isn't reaching the pump. Make sure the conduit isn't damaged, and that the wiring as well (i.e. in the event that it was struck by the lawn mower).

Signs Inside the Home

If your tank's pump doesn't move the old waste out of the tank the fresh water doesn't have any place to go. One of the first indicators you could observe is a gurgling sound within your pipes or your drains are draining slower than usual. The water leaking into your bathtubs, sinks and toilets as well as the stench of sewage in your home can be a sign that something's wrong in your septic tank.

Also Read: How Much Does 5 Gallons of Oil Weigh